SS Pressure Gauge, Bourdon Type SS Pressure Gauge, Stainless Steel Pressure gauge Manufacturers Gujarat, India

response@pressuregaugeindia.com | +91 9426395647

All SS Pressure Gauge

All SS Pressure Gauge

Bourdon type (Two Part Connection System)

All SS Pressure Gauge Send Enquiry

Special Features

  • Stainless steel case & measuring system
  • Rugged construction
  • Dry or liquid filled
  • Standard followed in general EN 837-1

Application

  • Food & beverage
  • Pumps
  • Engine compressors
  • Chemical
  • Diesel engines
  • Conventional
  • Equipments
  • Presses
  • Nuclear power plants
  • Pharmaceutical
  • Turbines
  • Hydraulic
  • Petrochemical industries Hydro-cleaning machines
  • Refrigerating plants and gaseous / liquid media that will not obstruct the pressure system.

Specifications

Standard Version : 50 mm, 63 mm & 80 mm

Accuracy± 1.6% of F.S.
Ambient temperature- 25°C to + 65°C
Process temperatureMax 180°C
Operating pressure75 % of Scale Value
Over pressure limit< 100 bar : 125% of Max. Scale Value
>    100 to < 600 bar : 115% of Max. Scale Value
>    600 to < 1600 bar: 110% of Max. Scale Value
Case & BezelAISI 304 SS (Crimped Bezel) / Optional Bayonet Bezel For NS 63 & 83mm(Option : SAB )
SocketAISI 316 SS
BourdonAISI 316LSS
MovementAISI 304 SS
JointsTig Argon Arc Welding

ProtectionIP 68
DialAluminium, black graduation on white background
PointerBlack Coloured, Fixed
WindowPlexi Glass
Filling PlugNeoprene
GasketNeoprene / Silicon rubber

Dry But Fillable Version (Option DFG)

Fillable Dampening LiquidGlycerine 99.7%
Ambient Temperature (-) to 65°C
Process TemperatureMaximum 65°C
Other FeaturesRefer Specification of Standard Version

Glycerine Filled Version (Option LFG)

Accuracy±1.6% of F. S.
Ambient TemperatureMaximum
Process TemperatureMaximum 65°C
WindowPlexi Glass
Dampening LiquidsGlycerine 99.7%
Other FeaturesRefer Specification of Standard Version

Temperature effect:

The variation of indication caused by effects of temperature is to be calculated by below formula; which is to be added in the specified accuracy while measurement:- Formula : ± 0.04 x (t2 -11) % of F. S. where t1 = reference temperature (+20°C) and t2 = ambient temperature in °C.

Download Brochure

Accessories

Bourdon Type

Diaphragm Sealed & Gauge

Differential Gauge

Digital Pressure and Temperature

Electrical Contact

Low Pressure Capsule & LPD & SCH Diaphragm

Manifold

Megnahellic DPG

Needle Valve

RTD

Special Gauges

Temperature Gauges

Thermowell

Temperature Sensor