Accuracy | ±1.0% of F. S. |
Ambient temperature | - 25°C to + 65°C |
Process temperature | Max 300°C |
Operating pressure range | 75% of Scale Value |
Over pressure limit | < 100 bar : 125% of Max. Scale Value > 100 to < 600 bar : 115% of Max. Scale Value > 600 to < 1600 bar: 110% of Max. Scale Value |
Case & Bezel | AISI 304 SS (Bayonet Type) |
Bourdon | AISI316SS |
Socket | AISI 304 SS (Directly Welded to Case) |
Movement | AISI 304 SS |
Joints | Tig Argon Arc Welding |
Protection | IP 68 |
Dial | Aluminium, black graduation on white background |
Pointer | Aluminium, black coloured Micrometer zero adjustable |
Window | Toughened Glass |
Blow off Disc | Neoprene |
Gasket & Filling Plug | Neoprene |
Dry But Fillable Version (Option DFG)
Fillable Dampening Liquid | Glycerine 99.7% (Option - DFG) |
Ambient Temperature | Maximum 65°C |
Process Temperature | Maximum 65°C |
Window | Toughened Glass |
Other Features | Refer Specification of |
Standard Version |
Glycerine Filled Version (Option LFG)
Accuracy | ±1.0% of F.S. |
Ambient Temperature | Maximum 65°C |
Process Temperature | Maximum 65°C |
Window | Toughened Glass |
Dampening Liquids | Glycerine 99.7% (others available as option) |
Other Features | Refer Specification of Standard Version |
The variation of indication caused by effects of temperature is to be calculated by below formula; which is to be added in the specified accuracy while measurement:- Formula : ± 0.04 x (t2 -11) % of F. S. where t1 = reference temperature (+20°C) and t2 = ambient temperature in °C.
Download Brochure