Stainless Steel Pressure Gauge, Bourdon Tube Pressure Gauge, Bourdon Type SS Pressure Gauge Manufacturers Gujarat, India

response@pressuregaugeindia.com | +91 9426395647

All SS (SS 304) Pressure Gauge

All SS (SS 304) Pressure Gauge

Bourdon type

All SS (SS 304) Pressure Gauge Send Enquiry

Special Features

  • External zero adjustment (optional)
  • Stainless steel case & measuring system
  • Socket directly welded to case
  • Dry and liquid filled version
  • Standard followed EN 837-1 (for NS 100, 150 & 250 mm)
  • CE marking (as per PED 97/23/EC) (for NS 100 mm & 150 mm)

Application

  • Cryogenics
  • Pumps
  • Diesel engines & Refrigerating plants
  • Chemical & Petrochemical industries
  • Conventional & nuclear power plants
  • Environments & gaseous or liquid media that will not obstruct the pressure system.
  • Hydro-cleaning machines
  • Presses
  • Engine compressors
  • Turbines

Specifications

Standard Version : 100 mm, 125 mm, 150 mm, 200 mm & 250 mm

Accuracy±1.0% of F. S.
Ambient temperature- 25°C to + 65°C
Process temperatureMax 300°C
Operating pressure range75% of Scale Value
Over pressure limit< 100 bar : 125% of Max. Scale Value
>    100 to < 600 bar : 115% of Max. Scale Value
>    600 to < 1600 bar: 110% of Max. Scale Value

Case & BezelAISI 304 SS (Bayonet Type)
BourdonAISI316SS
SocketAISI 304 SS (Directly Welded to Case)
MovementAISI 304 SS
JointsTig Argon Arc Welding
ProtectionIP 68
DialAluminium, black graduation on white background
PointerAluminium, black coloured Micrometer zero adjustable
WindowToughened Glass
Blow off DiscNeoprene
Gasket & Filling PlugNeoprene

Dry But Fillable Version (Option DFG)

Fillable Dampening LiquidGlycerine 99.7% (Option - DFG)
Ambient TemperatureMaximum 65°C
Process TemperatureMaximum 65°C
WindowToughened Glass
Other FeaturesRefer Specification of

Standard Version

Glycerine Filled Version (Option LFG)

Accuracy±1.0% of F.S.
Ambient TemperatureMaximum 65°C
Process TemperatureMaximum 65°C
WindowToughened Glass
Dampening LiquidsGlycerine 99.7% (others available as option)
Other FeaturesRefer Specification of Standard Version

Temperature effect:

The variation of indication caused by effects of temperature is to be calculated by below formula; which is to be added in the specified accuracy while measurement:- Formula : ± 0.04 x (t2 -11) % of F. S. where t1 = reference temperature (+20°C) and t2 = ambient temperature in °C.

Download Brochure

Accessories

Bourdon Type

Diaphragm Sealed & Gauge

Differential Gauge

Digital Pressure and Temperature

Electrical Contact

Low Pressure Capsule & LPD & SCH Diaphragm

Manifold

Megnahellic DPG

Needle Valve

RTD

Special Gauges

Temperature Gauges

Thermowell